loading

A premier electronic component distributor, focus on supplying and solving for new energy vehicle, motorcycle and BESS industries.

info@eshine-cd.com+86 18848211277

DC 500V JDA05-S Series Road Vehicle Fuse 100A to 400A 20kA Breaking Capacity Bolt-Down Protection for EV Battery Packs PDU and High-Voltage Junction Boxes 1
DC 500V JDA05-S Series Road Vehicle Fuse 100A to 400A 20kA Breaking Capacity Bolt-Down Protection for EV Battery Packs PDU and High-Voltage Junction Boxes 2
DC 500V JDA05-S Series Road Vehicle Fuse 100A to 400A 20kA Breaking Capacity Bolt-Down Protection for EV Battery Packs PDU and High-Voltage Junction Boxes 1
DC 500V JDA05-S Series Road Vehicle Fuse 100A to 400A 20kA Breaking Capacity Bolt-Down Protection for EV Battery Packs PDU and High-Voltage Junction Boxes 2

DC 500V JDA05-S Series Road Vehicle Fuse 100A to 400A 20kA Breaking Capacity Bolt-Down Protection for EV Battery Packs PDU and High-Voltage Junction Boxes

DESIGN REFERENCE:  JASO D622、ISO8820.8、GB/T31465、NBT10329-2019
RATED VOLTAGE:  500VDC
RATED CURRENT:  100A~400A
BREAKING CAPACITY:  20kA@2ms
CERTIFICATION:  RoHS
APPLICATION:  EV and HEV battery packs, Battery disconnect units (BDU), Power distribution units (PDU), High-voltage junction boxes, On-board chargers(OBC), DC/DC converters...





 
5.0
design customization

    oops...!

    no product data.

    Go to homepage

    Product features

    The JDA05-S series is a 500 VDC bolt-down fuse family built for the high-current circuits inside road vehicles: battery packs, power distribution units, high-voltage junction boxes, on-board chargers and motor drive paths. Eight ratings from 100 A to 400 A share one compact bolt-in format, so a single busbar design can cover several vehicle platforms without re-tooling.

    Every link interrupts up to 20 kA at 500 VDC with a 2 ms time constant. That margin matters in a pack-level short circuit, where available fault current rises fast and a slow element simply lets the arc run. Pre-arcing and total I²t are published for all eight ratings (3–42 kA²s and 9–140 kA²s), so coordination with contactors, relays and downstream fuses can be calculated instead of guessed.

    The element sits in a sealed, chemical-resistant body rated for −40 °C to +125 °C ambient and qualified to GB/T 28046.3 passenger-car body vibration plus rail class II shock. Terminals take M8 bolts at 12 ± 1.0 N·m. The series is tested to JASO D622, ISO 8820-8, GB/T 31465 and NB/T 10329-2019, and is RoHS compliant.

    Catalog Numbers Current
    ratings
    (A)
    I²t(kA²s) 1.0ln
    WATTS
    KOSS( W)
    Size Installation
    torque
    Rre-arc Clearing
    JDA05-S-100A500V 100  3  9  9  JDA05-S M8:
    12±1.0N ·m
    JDA05-S-125A500V 125  4  14  12 
    JDA05-S-150A500V 150  6  20  16 
    JDA05-S-200A500V 200  11  35  21 
    JDA05-S-250A500V 250  17  57  27 
    JDA05-S-300A500V 300  24  81  36 
    JDA05-S-350A500V 350  32  106  45 
    JDA05-S-400A500V 400  42  140  52 
    JDA05-S-01-100A500V 100  3  9  9  JDA05-S-01 M8:
    12±1.0N ·m
    JDA05-S-01-125A500V 125  4  14  12 
    JDA05-S-01-150A500V 150  6  20  16 
    JDA05-S-01-200A500V 200  11  35  21 
    JDA05-S-01-250A500V 250  17  57  27 
    JDA05-S-01-300A500V 300  24  81  36 
    JDA05-S-01-350A500V 350  32  106  45 
    JDA05-S-01-400A500V 400  42  140  52 
    Note: I²t above is 20kA@2ms Typical data during breaking for reference

    -500 VDC rated voltage — a real 400/500 V platform part. Not a 32 V or 58 V automotive fuse pushed beyond its arc-quenching limit; the element and body are designed for 500 VDC breaking duty.

    -20 kA breaking capacity at 500 VDC / 2 ms. Handles battery-pack-level prospective fault current, so a single main fuse can sit close to the pack terminals where fault current is highest.

    -Eight ratings from 100 A to 400 A. 100, 125, 150, 200, 250, 300, 350 and 400 A — enough steps to run at 50% of rating for continuous load without jumping a whole frame size.

    -Published pre-arcing and total I²t for every rating. 3/9 kA²s at 100 A up to 42/140 kA²s at 400 A, measured at 20 kA breaking. Coordination studies get real numbers, not a curve you have to eyeball.

    -Two body variants, one electrical platform. JDA05-S and JDA05-S-01 share identical ratings and I²t, differing in terminal/body configuration so different busbar and bracket layouts can use the same fuse family.

    -M8 bolt-down terminals at 12 ± 1.0 N·m. A defined torque window gives repeatable contact resistance and keeps the joint stable under vibration — no blade-in-clip fretting.

    -Wide ambient range: −40 °C to +125 °C permissible. Normal operation is specified from −5 °C to +50 °C; the wider window covers cold-crank, engine-bay and under-hood heat soak without changing part number.

    -Vibration and shock qualified to GB/T 28046.3. Meets passenger-car elastic-body vibration requirements, and the same construction is rated for rail transit class II shock environments.

    -Compact footprint, high power density. Up to 400 A continuous class in a bolt-in package that fits inside a PDU or junction box rather than beside it.

    -Typical applications. EV and HEV battery packs · battery disconnect units (BDU) · power distribution units (PDU) · high-voltage junction boxes · on-board chargers · DC/DC converters · motor controller feed · cabin heater and compressor high-voltage branches · electric buses and commercial vehicles · DC fast-charging equipment · 500 VDC industrial and stationary DC power circuits.

    Q&A

    1
    Can I use these fuses on an 800 V platform?
    No. The series is rated 500 VDC. On an 800 V architecture the DC arc is harder to extinguish and the fuse would be operated beyond its qualified breaking voltage. Use a fuse family rated for 800 VDC or above instead.
    2
    How much current can it actually carry continuously?
    The rated current is a test condition, not a continuous-load rating. For long-term service, keep the working current at or below 50% of the rating, then apply the Kt factor if the surrounding air exceeds 50 °C and the altitude derating if the fuse sits in an enclosure above 2000 m. A 300 A link in a 70 °C box will carry considerably less than 300 A.
    3
    What mounting torque and orientation do you recommend?
    Torque the M8 terminals to 12 ± 1.0 N·m, and hold the bolt while tightening the nut so the terminal cannot rotate and damage the element connection. Vertical, horizontal and inclined mounting are all acceptable. Keep the installation surface clean and stress-free, and leave adequate clearance between adjacent fuses — add an insulating barrier between them if live-part clearance during replacement is tight.

    Related Products

    Chengdu Eshine Technology was established in 2009. It is an overall solution provider integrating brand agency of electronic components and technical support services. 

    Let's talk about your  project now.

    Developing a new unique light is easy here in samuel.
    ●  Professional feedback within 8 hour
    ●  Full capabilities to rely on
    ●  Best possible prices for you
    ●  Fast prototype in 1 week
    ●  Fast delivery in 35-40 days
    Get in touch with us

    +86 28 86519933

    Operating hours
    Monday - Friday(GMT+8): 9am - 6pm  Saturday: 9am - 4pm
    Chengdu Eshine Technology was established in 2009. It is an overall solution provider integrating brand agency of electronic components and technical support services. 
    Contact with us
    Tel: +86 28 86519933
    WeChat/WhatsApp: +86 191 4130 7053
    Company Address: No. 101, Building 22, Zhongjian Jinyuanhui Plaza, No. 299 Yinglong South Road 1, Gaoxin District, Chengdu, China
    Copyright © 2026 ChengDu Eshine Technology Co.,Ltd. - www.eshine-cd.com | Sitemap
    Contact us
    whatsapp
    Contact customer service
    Contact us
    whatsapp
    cancel
    Customer service